APC Butterfly Valves

Kitz SCT APC Valve product.

APC Butterfly Valves

The APC Valve replaces and performs the function of four different valves: Isolation and slow start for bypass line, Isolation and auto pressure control for main line. The optional internal and external heaters maintain fluid temperature with a maximum temperature of 190C.

Product Details

MAIN SPECIFICATIONS
Maximum Operation Pressure1x10-6Pa~0.101MPa (1x10-5 Torr~760Torr)
Leak Rates (with FKM)Across the Seat He Leak Test Rates: 5 x 10-10 Pa·m3/sec or less
Inboard He Leak Test Rates: 1 x 10-8 Pa·m3/sec or less
Differential Pressure0.101MPa
Response TimeFull open <-> Full close (Flapper + Seat ring): About 1 sec
Cycle Life3 million (Full open <-> Full close) *3
Atmospheric Temperature5~50°C (41~122F)
MaterialBody, Flapper : 316L,
Others : Aluminum, SUS304 equivallent
Sealing (O-ring) : FKM
Power-supply VoltageDC24V+10%-5% (3A MAX)
Network InterfaceDeviceNetTM ,RS232C, Analog, EtherCAT*
*Ask the detail of EatherCAT
Interface ConnectionHigh Density subminiature D male connector 26P
Pressure Sensor InputMax 3ch (0-5 V, 0-10 V)
*1. 40A and 50A flanges are optional.
*2. Conductance rate depends on pressure. Ask it in detail to sales.
*3. FKM, 150°C, Own test, actual result
*4. In case of using Kalrez (R), set the heater temperature to100°C or higher.
Flange size40A50A65A80A100A
Conductance23.1ℓ/s49ℓ/s66.0ℓ/s181ℓ/s342ℓ/s
Weight11.9kg (26.2lbs)12.2kg (26.9lbs)13.5kg (29.8lbs)13.8kg (30.4lbs)15.8kg (34.8lbs)
Accessories
· Power inlet cable (5 meter (16.404 ft))
· Interface connector
· Sensor connector
OPTION
UPSEmergency shut off when power failure
Seal material (O-ring)Kalrez 8900®, Kalrez 9100® *4
HeaterHHIHH
External Heater50A:AC200V 160W, 80A:AC200V 195W,
100A:AC200V 226W
80A:AC200V 278W
Internal HeaterAC200V 60WAC200V 60W
Maximum Operating Temperature150°C (302F)190°C (374F)
ThermocoupleExternal: K-type Teflon coated, ungrounded type x 1
Internal: K-type Teflon coated, ungrounded type x 1
ThermostatExternal only: N.O (Automatic re-set)
Ask our sales for other options.
PRODUCT CODE KEY
Model
Body Size
Flange
Connection
Flange
Size
Flange
Seat Material
Network Interface
Controller
Heater
UPS
PCA
50
-
NW
40
F
-
A
V
-
HI
-
U
50: 50A
80: 80A
100: 100A
NW: ISO KF
JF: JIS VF-VG
Not Shown: Same as body
40: 40A *1
65: 65A *1
O-ring material
F: FKM
KL8900: Kalrez 8900
KL9100: Kalrez 9100
A: Analog
R: RS232C
D: DeviceNET™
E: EtherCAT
Not Shown: On the Body
V: Separated
None: Analog
H: External Heater
HI: External and Internal Heater
HH: External and Internal Heater 190℃
Not Shown: Without UPS
U: With UPS

*1. Our 40A size uses our 50A body. Our 65A size uses 80A size body.
Items with "*" are optional.